TC Block
June 2020
2
General Description
Functional Description and Hydraulic Symbol
Technical Specification
Temperature Compensating Block for indication of end positions
(VPI-V or VPI-E). The TC-Block allows the expansion/contraction
of the oil in the system caused by major temperature and
pressure variations without influencing the end stops and the
switch functions of the indicator.
The Block is provided with Cetop-3 connection for mounting
of pilot valve. The combination of the VPI indicator and the TC-
Block can be used for all DKMS-actuators and is used at on/off
controls .
The function of the TC-Block is to allow the oil only to flow through
the VPI in the required direction (locks and acknowledges the el.
on/off signal). The undesired contra-flow is bypassing the VPI,
thus avoiding an electrical signal failure with resulting “alarm
signal”. This undesired oil flow is caused by the temperature
expansion/contraction of the oil and also by a fluctuating
pressure in the system at an on/off-operated actuator.
Note!
The TC-Block is always to be used together with a 4/2-way
control valve.
Pilot valve side/CETOP-3 connection
Indicator side/VPI connection
Max. working pressure 135 bar
~
1958 lbf/in2
Max. test pressure 205 bar
~
2973 lbf/in2
Max. flow rate at 135 bar / 1958 lbf/in2 (through any line) 15 l/min.
Weight 1,2 kg.
~
2,65 lb
Hydraulic media Acid-free hydraulic oil
Viscosity 15-200 cSt
Filtration requirements 25 μm absolute or finer
Temperature range -20°C to 80°C
Connection face CETOP R 35H size 3, DIN 24340/VPI connection